Human C1q ELISA Kit

For the quantitative in vitro determination of Human Complement 1q

concentrations in

 serum - plasma - celiac fluid - tissue homogenate - body fluid

 

 

 

 

 

 

FOR LABORATORY RESEARCH USE ONLY.

NOT FOR USE IN DIAGNOSTIC PROCEDURES.

 

 

This package insert must be read in its entirety before using this product.

 

ELISA

ENZYME LINKED IMMUNOSORBENT ASSAY

INTENDED USE AND TEST PRINCIPLE

This C1q ELISA kit is intended Laboratory for Research use only and is not for use in diagnostic or therapeutic procedures. The Stop Solution changes the color from blue to yellow and the intensity of the color is measured at 450 nm using a spectrophotometer. In order to measure the concentration of C1q in the sample, this C1q ELISA Kit includes a set of calibration standards. The calibration standards are assayed at the same time as the samples and allow the operator to produce a standard curve of Optical Density versus C1q concentration. The concentration of C1q in the samples is then determined by comparing the O.D. of the samples to the standard curve.

 

SAMPLE COLLECTION AND STORAGES

Serum - Use a serum separator tube and allow samples to clot for 2 hours at room temperature or overnight at 4℃ before centrifugation for 20 minutes at approximay 2000×g. Remove serum and assay immediay or aliquot and store samples at -20℃. Avoid repeated freeze-thaw cycles

Plasma - Collect plasma using heparin as an anticoagulant. Centrifuge samples for 30 minutes at 2000×g at 2-8℃ within 30 minutes of collection. Store samples at -20℃. Avoid repeated freeze-thaw cycles.

Cell culture supernates, tissue homogenate and other biological fluids - Remove particulates by centrifugation and assay immediay or aliquot and store samples at -20℃. Avoid repeated freeze-thaw cycles.

Note:  The samples shoule be centrifugated dequay and no hemolysis or granule was allowed.

 

MATERIALS REQUIRED BUT NOT SUPPLIED

1.  37 ℃ incubator

2.  Standard microplate reader capable of measuring absorbance at 450 nm

3.  Precision pipettes, disposable pipette tips and Absorbent paper

4.  Distilled or deionized water

 

REAGENTS PROVIDED

All reagents provided are stored at 2-8°C. Refer to the expiration date on the label.

 

Name

96 determinations

48 determinations

Microelisa stripplate

12*8strips

12*4strips

Standard(6 vial)

0.5ml/vial

0.5ml/vial

Sample diluent

6.0ml

3.0ml

HRP-Conjugate reagent

10.0ml

5.0ml

20X Wash solution

25ml

15ml

Chromogen Solution A

6.0ml

3.0ml

Chromogen Solution B

6.0ml

3.0ml

Stop Solution

6.0ml

3.0ml

Closure plate membrane

2

2

User manual

1

1

Sealed bags

1

1

Note:

1.  Standard concentration was followed by: 320、160、80、40、20、10 ug/mL.

2.  If samples generate values higher than the highest standard, please dilute the samples with Sample Diluent and repeat the assay.

 

PRECAUTIONS

  1. Do not substitute reagents from one kit lot to another. Standard, conjugate and microtiter plates are matched for optimal performance. Use only the reagents supplied by manufacturer.
  2. Allow kit reagents and materials to reach room temperature (20-25°C) before use. Do not use water baths to thaw samples or reagents.
  3. Do not use kit components beyond their expiration date.
  4. Use only deionized or distilled water to dilute reagents.
  5. Do not remove microtiter plate from the storage bag until needed. Unused strips should be stored at 2-8°C in their pouch with the desiccant provided.
  6. Use fresh disposable pipette tips for each transfer to avoid contamination.
  7. Do not mix acid and sodium hypochlorite solutions.
  8. Serum and plasma should be handled as potentially hazardous and capable of transmitting disease. Disposable gloves must be worn during the assay procedure, since no known test method can offer complete assurance that products derived from Rat blood will not transmit infectious agents. Therefore, all blood derivatives should be considered potentially infectious and good laboratory practices should be followed.
  9. All samples should be disposed of in a manner that will inactivate viruses.
  10. Liquid Waste: Add sodium hypochlorite to a final concentration of 1.0%. The waste should be allowed to stand for a minimum of 30 minutes to inactivate the viruses before disposal.
  11. Substrate Solution is easily contaminated. If bluish prior to use, do not use.
  12. Substrate B contain 20% acetone, keep this reagent away from sources of heat or flame.
  13. Remove all kit reagents from refrigerator and allow them to reach room temperature ( 20-25°C).

 

REAGENT PREPARATION AND STORAGE

Wash Solution (1X) - Dilute 1 volume of Wash solution (20X) with 19 volumes of deionized or distilled water. Wash Solution is stable for 1 month at 2-8°C.

 

ASSAY PROCEDURE

1.  Prepare all reagents before starting assay procedure. It is recommended that all Standards and Samples be added in duplicate to the Microelisa Stripplate.

2.  Add 50μl of Standard or Sample to the appropriate wells. Blank well doesn’t add anyting.

3.  Add 100μl of HRP-conjugate reagent to standard wells and sample wells except the blank well, cover with an adhesive strip and incubate for 60 minutes at 37°C.

4.  Wash the Microtiter Plate 4 times.

Manual Washing - Remove incubation mixture by aspirating contents of the plate into a sink or proper waste container. Using a squirt bottle, fill each well compley with Wash Solution (1X), then aspirate contents of the plate into a sink or proper waste container. Repeat this procedure for a total of four times. After final wash, invert plate, and blot dry by hitting plate onto absorbent paper or paper towels until no moisture appears. Note: Hold the sides of the plate frame firmly when washing the plate to assure that all strips remain securely in frame.

Automated Washing - Aspirate all wells, then wash plates four times using Wash Buffer (1X). Always adjust your washer to aspirate as much liquid as possible and set fill volume at 350μL/well/wash. After final wash, invert plate, and blot dry by hitting plate onto absorbent paper or paper towels until no moisture appears.

5.  Add chromogen solution A 50μl and chromogen solution B 50μl to each well. Gently mix and incubate for 15 minutes at 37°C. Protect from light.

6.  Add 50μl Stop Solution to each well. The color in the wells should change from blue to yellow. If the color in the wells is green or the color change does not appear uniform, gently tap the plate to ensure thorough mixing.

7.  Read the Optical Density (O.D.) at 450 nm using a microtiter plate reader within 15 minutes.

 

CALCULATION OF RESULTS

  1. This standard curve is used to determine the amount in an unknown sample. The standard curve is generated by plotting the average O.D. (450 nm) obtained for each of the six standard concentrations on the vertical (X) axis versus the corresponding concentration on the horizontal (Y) axis.
  2. First, calculate the mean O.D. value for each standard and sample. All O.D. Values are subtracted by the mean value of the balnk well before result interpretation. Construct the standard curve using graph paper or statistical software.
  3. To determine the amount in each sample, first locate the O.D. value on the Y-axis and extend a horizontal line to the standard curve. At the point of intersection, draw a vertical line to the X-axis and read the corresponding concentration.
  4. Any variation in operator, pipetting and washing technique, incubation time or temperature, and kit age can cause variation in result. Each user should obtain their own standard curve.
  5. Intra-assay CV(%) and Inter-assay CV(%)are less than 15%.
  6. Assay range: 10ug/mL – 320 ug/mL.

7.  Sensitivity: The minimum detectable dose of Human C1q is typically less than 10 ug/mL.

8.  Cross-reactivity: This assay recognizes recombinant and natural Human C1q. No significant cross-reactivity or interference was observed.

9.  Storage: 2-8℃ (Use frequently); six months (-20℃)。

10.  Standard curve

 

 

FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH ENTIRE PROCEDURE BEFORE BEGINNING!

上海逸峰生物科技有限公司作者

上一篇:巖棉板質量直接影響外墻整體安全

下一篇:巖棉板是否可以用在舊樓改造使用?


我要投稿
  • 投稿請發(fā)送郵件至:(郵件標題請備注“投稿”)hbzhan@vip.qq.com
  • 聯系電話0571-87759680
環(huán)保行業(yè)“互聯網+”服務平臺
環(huán)保在線APP

功能豐富 實時交流

環(huán)保在線小程序

訂閱獲取更多服務

微信公眾號

關注我們

抖音

環(huán)保在線網

抖音號:hbzhan

打開抖音 搜索頁掃一掃

視頻號

環(huán)保在線

公眾號:環(huán)保在線

打開微信掃碼關注視頻號

快手

環(huán)保在線

快手ID:2537047074

打開快手 掃一掃關注
意見反饋
精品美女久久久久久嘘嘘| 操烂嫩逼内射视频| 日本公共厕所mmm撒尿| 普通话大屌操小穴| 热精品韩国毛久久久久久| 国产一区曰韩二区欧美三区| aaa啊啊啊黄片| 日韩人妻无码中字一区二区| a一级毛片免费高清在线| 久久综合久久久久综合大| 国产精品亚洲一区二区三区极品| 最新国产亚洲亚洲精品A| 色一情一交一乱一区二区| 巨屌抽插舔阴视频| 久久精品国产亚洲av伦理| 国产亚洲欧美中文日韩| 日韩美女一区二区三区香蕉视频| 久久国产亚洲高清| 大鸡巴插入骚穴在线观看| 美女被插入小穴涩涩视频| 久久久久黑人强伦姧人妻| 男生鸡鸡插进女生笑穴里| 国产午夜久久精品一区四虎| 潮中文字幕在线观看| 成人毛片一级特黄| 视频在线观看一区@99| 亚洲美女后入在线播放| 黄色录像片操大逼的| avtt天堂网先锋伦理| 在线免费观看一区二区三区| 日韩美女一区二区三区香蕉视频| 老司机免费福利午夜入口| 找个日韩操逼的看看| 中文字幕在线观一二三区| 亚洲高清无遮挡在线观看| 伊人久久丁香色婷婷啪啪| 欧美亚洲熟妇视频在线观看| 欧美99热这里都是精品| 少妇精品久久久一区二区免费| 中文字幕在线资源第一页| 国产亚洲精品高清视频免费|